Run a qualitative respirator fit test
Practice the sequence you already learned for “Run a qualitative respirator fit test” until the order feels automatic. Drill OSHA 1910.134 Appendix A from respiratory-program training. The fit test is not scored until sensitivity is confirmed and the required exercises are completed.
- Confirm medical clearance for the wearer.
- Confirm the wearer is clean-shaven where the seal sits.
- Perform the sensitivity screening with the hood and no respirator.
- Have the wearer don the assigned make, model, and size.
- Run the user seal check before the fit-test agent is introduced.
- Run the required exercise set with the test agent.
- Fail the test if the wearer detects the agent at any exercise.
- Record the pass or fail result.
- Do not send a failed wearer into the hazard on that facepiece.