Collect an environmental water sample under chain of custody
Practice the EPA CLP / ISO 17025 field-sampling order. The COC header is started with site metadata before the bottle is filled, and the cooler is not relinquished without matching labels and signatures.
- Record site ID, GPS, date, time, and weather on the field sheet.
- Start the chain-of-custody header with sampler, site, and planned analyses.
- Don the required gloves.
- Do not touch the bottle lip or the inside of the cap.
- Rinse or preserve the bottle exactly as the method requires.
- Collect at the specified depth, facing upstream if surface water.
- Cap the bottle immediately.
- Label with the unique sample ID that matches the COC.
- Bag or apply the custody seal.
- Place the sample on ice.
- Complete the COC time, preservative, and container-count entries.
- Relinquish the cooler only to the lab courier with both signatures.